The Journal of Emergency Medicine
Volume 41, Issue 1 , Pages 64-73, July 2011

Detection and Localization of Peripheral Vascular Bleeding Using Doppler Ultrasound

  • Wenbo Luo, PhD

      Affiliations

    • Department of Bioengineering, University of Washington, Seattle, Washington
    • Corresponding Author InformationReprint Address: Wenbo Luo, phd, Department of Bioengineering, University of Washington, Box 355061, Seattle, WA 98195
  • ,
  • Hamid Hosseini, PhD

      Affiliations

    • Department of Bioengineering, University of Washington, Seattle, Washington
  • ,
  • Vesna Zderic, PhD

      Affiliations

    • Department of Electrical and Computer Engineering, The George Washington University, Washington, DC
  • ,
  • Frederick Mann, MD

      Affiliations

    • Seattle Radiologists, Seattle, Washington
  • ,
  • Grant O'Keefe, MD

      Affiliations

    • Department of Surgery, University of Washington, Seattle, Washington
  • ,
  • Shahram Vaezy, PHD

      Affiliations

    • Department of Bioengineering, University of Washington, Seattle, Washington

Received 15 September 2009; received in revised form 11 November 2009; accepted 5 January 2010. published online 02 March 2010.

Abstract 

Background: Hemorrhage from wounds in the extremities is the leading cause of preventable death on the battlefield. To successfully treat these injuries, the exact source of bleeding must be localized. Objective: The purpose of this study was to determine the feasibility of using Doppler ultrasound to precisely detect and localize peripheral vascular bleeding. Methods: Injuries were produced in common femoral arteries (diameter of ∼5 mm) of 28 pigs in vivo. Single puncture injuries were produced using 6 French (F) (n = 10), 9 F (n = 22), and 12 F (n = 12) catheters. In addition, multiple punctures were made (using 6 F and 9 F catheters) in eight common femoral arteries to simulate bleeding from multiple injuries. Finally, laceration injuries were produced using a scalpel in 10 femoral vessels. Results: In color Doppler images, bleeding was observed as a turbulent jet flow originating from the injury site in the vessel. This jet flow had checkered red-blue color pattern at the bleeding site, as opposed to a uniform color pattern in an intact artery. Peak systolic velocity at the injury site, measured using pulsed Doppler, was elevated to up to 152.0 ± 81.6 cm/s, as compared to 78.8 ± 17.5 cm/s in normal arteries. Further, end diastolic velocity increased from 6.1 ± 4.9 cm/s before the injury to up to 59.1 ± 33.1 cm/s after the injury. Resistance index was significantly lower (0.6 for 9 F and 12 F punctures, and 0.8 for 6 F punctures) at the bleeding site in injured arteries as compared to the resistance index of intact arteries (of 0.9). Conclusion: Our results showed a characteristic change in the systolic and diastolic velocities, as well as resistance indices at the injury site in peripheral arteries. These findings may serve as groundwork for development of automated bleeding detection and localization methods, and facilitate various hemorrhage control treatments.

Keywords: bleeding detection and localization, vascular injuries, Doppler ultrasound, color Doppler, arterial bleeding

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0736-4679(10)00002-8

doi:10.1016/j.jemermed.2010.01.001

The Journal of Emergency Medicine
Volume 41, Issue 1 , Pages 64-73, July 2011