Advertisement

Fraction of Expired Oxygen as a Measure of Preoxygenation Prior to Rapid Sequence Intubation in the Pediatric Emergency Department

      Abstract

      Background

      Pulse oximetry (SpO2) is a flawed measure of adequacy of preoxygenation prior to intubation. The fraction of expired oxygen (FeO2) is a promising but understudied alternative.

      Objective

      To investigate FeO2 as a measure of preoxygenation prior to intubation in a pediatric emergency department.

      Methods

      We conducted a prospective, observational study of patients 18 and younger. We collected data using video review, and FeO2 was measured via inline sampling. The main outcomes were FeO2 and SpO2 at the start of preoxygenation, end of preoxygenation/start of intubation attempt, and the end of intubation attempt. We compared FeO2 and SpO2 at the end of preoxygenation for patients with and without oxyhemoglobin desaturation.

      Results

      We enrolled 85 of 88 eligible patients during the 14-month study period. FeO2 data were available at the start of preoxygenation for 53 of 85 patients (62%), and for the end of preoxygenation for 59 of 85 patients (69%). Median FeO2 at the start and end of preoxygenation was 90% (interquartile range [IQR] 88, 92) and 90% (IQR 88, 92). Median SpO2 at the start and end of preoxygenation was 100% (IQR 100, 100). There were 11 episodes of desaturation, with median FeO2 at the start of intubation attempt of 89.5 (IQR 54.5, 91.5) and median SpO2 of 100 (IQR 99, 100). Patients who did not have a desaturation event had a median FeO2 of 90.0 (IQR 88.0, 92.0).

      Conclusions

      Measuring FeO2 during rapid sequence intubation is challenging with feasibility limitations, but may be a more discriminatory metric of adequate preoxygenation.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Emergency Medicine
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Brown 3rd, CA
        • Bair AE
        • Pallin DJ
        • Walls RM
        NEAR III Investigators. Techniques, success, and adverse events of emergency department adult intubations.
        Ann Emerg Med. 2015; 65 (e1): 363-370
        • Lee JH
        • Nuthall G
        • Ikeyama T
        • et al.
        Tracheal intubation practice and safety across international PICUs: a report from National Emergency Airway Registry for Children.
        Pediatr Crit Care Med. 2019; 20: 1-8
        • Pallin DJ
        • Dwyer RC
        • Walls RM
        Brown CA 3rd; NEAR III Investigators. Techniques and trends, success rates, and adverse events in emergency department pediatric intubations: a report from the National Emergency Airway Registry.
        Ann Emerg Med. 2016; 67 (e1): 610-615
        • Okubo M
        • Gibo K
        • Hagiwara Y
        • Nakayama Y
        • Hasegawa K
        Japanese Emergency Medicine Network Investigators. The effectiveness of rapid sequence intubation (RSI) versus non-RSI in emergency department: an analysis of multicenter prospective observational study.
        Int J Emerg Med. 2017; 10: 1
        • Rinderknecht AS
        • Mittiga MR
        • Meinzen-Derr J
        • Geis GL
        • Kerrey BT.
        Factors associated with oxyhemoglobin desaturation during rapid sequence intubation in a pediatric emergency department: findings from multivariable analyses of video review data.
        Acad Emerg Med. 2015; 22: 431-440
        • Li S
        • Hsieh T-C
        • Rehder KJ
        • et al.
        Frequency of desaturation and association with hemodynamic adverse events during tracheal intubations in PICUs.
        Pediatr Crit Care Med. 2018; 19: e41-e50
        • Walls R
        • Murphy M.
        Manual of emergency airway management.
        Wolters Kluwer Health, Philadelphia2012
        • Sagarin MJ
        • Chiang V
        • Sakles JC
        • et al.
        Rapid sequence intubation for pediatric emergency airway management.
        Pediatr Emerg Care. 2002; 18: 417-423
        • Kerrey BT
        • Mittiga MR
        • Rinderknecht AS
        • et al.
        Reducing the incidence of oxyhaemoglobin desaturation during rapid sequence intubation in a paediatric emergency department.
        BMJ Qual Saf. 2015; 24: 709-717
        • Jensen LA
        • Onyskiw JE
        • Prasad N.
        Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults.
        Heart Lung. 1998; 27: 387-408
        • Machlin HA
        • Myles PS
        • Berry CB
        • Butler PJ
        • Story DA
        • Heath BJ.
        End-tidal oxygen measurement compared with patient factor assessment for determining preoxygenation time.
        Anaesth Intensive Care. 1993; 21: 409-413
        • Meriläinen PT.
        A differential paramagnetic sensor for breath-by-breath oximetry.
        J Clin Monit. 1990; 6: 65-73
        • Myles P
        • Heap M
        • Langley M.
        Agreement between the measurement of end-tidal oxygen concentration and the ideal alveolar gas equation: pre-and post-cardiopulmonary bypass.
        Anaesth Intensive Care. 1993; 21: 240-241
        • Frerk C
        • Mitchell VS
        • McNarry AF
        • et al.
        Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.
        Br J Anaesth. 2015; 115: 827-848
        • Caputo ND
        • Oliver M
        • West JR
        • Hackett R
        • Sakles JC.
        Use of end tidal oxygen monitoring to assess preoxygenation during rapid sequence intubation in the emergency department.
        Ann Emerg Med. 2019; 74: 410-415
        • Nimmagadda U
        • Salem MR
        • Crystal GJ.
        Preoxygenation: physiologic basis, benefits, and potential risks.
        Anesth Analg. 2017; 124: 507-517
        • Butler P
        • Munro H
        • Kenny M.
        Preoxygenation in children using expired oxygraphy.
        Br J Anaesth. 1996; 77: 333-334
        • Morrison Jr, JE
        • Collier E
        • Friesen RH
        • Logan L.
        Preoxygenation before laryngoscopy in children: how long is enough?.
        Paediatr Anaesth. 1998; 8: 293-298
        • Chiron B
        • Mas C
        • Ferrandiere M
        • et al.
        Standard preoxygenation vs two techniques in children.
        Paediatr Anaesth. 2007; 17: 963-967
        • Kerrey BT
        • Rinderknecht A
        • Mittiga M.
        High risk, low frequency: optimizing performance of emergency intubation for children.
        Ann Emerg Med. 2017; 70: 783-786
        • Kerrey BT
        • Rinderknecht AS
        • Geis GL
        • Nigrovic LE
        • Mittiga MR.
        Rapid sequence intubation for pediatric emergency patients: higher frequency of failed attempts and adverse effects found by video review.
        Ann Emerg Med. 2012; 60: 251-259
        • Shah A
        • Edmunds K
        • Frey M
        • Kerrey B
        • Boyd S
        • Ahaus K.
        Don't hold your breath! Procedural inefficiencies during rapid sequence intubation in a pediatric emergency department: a detailed video analysis.
        Pediatrics. 2020; 146: 201-202
        • Von Elm E
        • Altman DG
        • Egger M
        • Pocock SJ
        • Gøtzsche PC
        • Vandenbroucke JP.
        The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies.
        Ann Intern Med. 2007; 147: 573-577
        • Kerrey BT
        • Mittiga MR
        • Rinderknecht AS
        • et al.
        Reducing the incidence of oxyhaemoglobin desaturation during rapid sequence intubation in a paediatric emergency department.
        BMJ Qual Saf. 2015; 24: 709-717
        • Harris PA
        • Taylor R
        • Thielke R
        • Payne J
        • Gonzalez N
        • Conde JG.
        Research electronic data capture (REDCap)–a metadata-driven methodology and workflow process for providing translational research informatics support.
        J Biomed Inform. 2009; 42: 377-381